The JBP Nano revolutionizes injection therapy with Japanese nanotechnology featuring ultra-thin walls (0.20mm) and Micron Sharpness polishing. Clinically proven to reduce pain by >60% and tissue trauma by 68%, this //system delivers 150% improved viscosity flow for virtually bloodless aesthetic procedures. Precision-engineered for professional dermatological applications.

Quantity discounts
Quantity Discount Price
5-9 3% $82.45
10-19 5% $80.75
20-Unlimited 8% $78.20
SKU: FF-JBPN Categories:
5% OFF Want to save more? - Pay with WISE for an extra 5% off.
Ultra-thin-wall injection needle · Sterile single-use

This is an ultra-thin-wall injection needle whose 0.20 mm outer wall and micron-polished bevel maximise the inner lumen while keeping the puncture small. It is offered in a range of gauge and length options so clinicians can match the needle to the solution and depth.

Type
Ultra-thin-wall needle
Gauges
23G–33G options
Lengths
4–25 mm
Form
Sterile, single-use (EO)
Overview

What it is

A precision injection needle built with an ultra-thin wall (0.20 mm class) and a micron-polished, triple-bevel tip. The thin wall widens the internal lumen for a given outer size, easing the flow of viscous solutions.

Sizes available

Selectable by model — gauges from 23G down to 33G in lengths of roughly 4 to 25 mm — so the same line covers superficial skin-booster work through deeper, higher-viscosity filler delivery.

How it is used

Designed for shallow insertion (about 10–15° for dermal planes) with a slow, controlled extrusion rate; finer 33G tips suit low-viscosity solutions and botulinum toxin, while 25–27G suit higher-viscosity HA.

Sterility

Each needle is sterile, single-use and ethylene-oxide sterilised; it must not be bent, reshaped or reused.

Technical data
Wall / lumen Ultra-thin wall, 0.20 mm class — widened inner lumen
25G 13 / 25 mm; ID 0.26 mm / OD 0.51 mm — deep subcutaneous, high-viscosity HA
27G 13 / 25 mm; ID 0.20 mm / OD 0.41 mm — mid-to-deep dermis
30G 4 / 8 / 13 mm; ID 0.20 mm / OD 0.30 mm — superficial dermis, skin boosters
33G 4 / 8 / 13 mm; ID 0.16 mm / OD 0.26 mm — epidermal, botulinum toxin, low viscosity
Technique Insertion 10–15°; extrusion <0.1 mL/sec
Sterilisation Ethylene-oxide (EO); sterile, single-use
Limits 33G not for solutions above ~600 mPa·s; 25G and larger not for periosteal contact
For practitioners
  1. Select the gauge and length to match the solution’s viscosity and the target depth (e.g. 33G for low-viscosity/botulinum, 25–27G for higher-viscosity HA).
  2. Insert at a shallow 10–15° for dermal planes and keep the extrusion rate below 0.1 mL/sec.
  3. Do not use 33G tips for solutions above ~600 mPa·s, to avoid excessive extrusion pressure.
  4. Avoid periosteal contact with 25G and larger sizes.
  5. Open the sterile needle immediately before use; never bend, reshape, re-sterilise or reuse it.
  6. Dispose of used needles as clinical sharps per local regulations.
FAQ
What does ‘ultra-thin wall’ mean here?

The needle wall is thinner than a standard needle of the same outer gauge, which widens the inner lumen. That lets a given outer size pass more solution with less force, so a finer-looking needle can still deliver viscous material.

What gauges and lengths are available?

It is offered across a range of models — gauges from 23G to 33G in lengths of about 4 to 25 mm — chosen on the product page to suit the procedure.

Which size should I use for which solution?

As a guide: 33G (4–13 mm) suits low-viscosity solutions and botulinum toxin; 30G suits superficial dermis and skin boosters; 25–27G suit higher-viscosity HA and deeper placement. The clinician makes the final choice.

What are the inner and outer diameters?

They vary by gauge — for example 33G is about 0.16 mm inner / 0.26 mm outer, 30G about 0.20 / 0.30 mm, 27G about 0.20 / 0.41 mm, and 25G about 0.26 / 0.51 mm.

Is there a viscosity limit?

Yes. The finest 33G needles are not recommended for solutions above roughly 600 mPa·s, because the extrusion pressure required becomes too high.

Is it reusable?

No. Each needle is sterile, ethylene-oxide sterilised and strictly single-use. It must not be bent, reshaped, re-sterilised or reused.

What injection angle and speed are recommended?

For dermal planes, a shallow insertion of about 10–15° with a slow extrusion rate under 0.1 mL/sec helps control placement and comfort.

Who should use it?

It is a professional single-use medical device for licensed, trained practitioners, who should dispose of used needles as clinical sharps.

Regulatory & safety notice. This is a sterile, single-use injection needle for professional use only. Do not bend, reshape, re-sterilise or reuse it; observe the viscosity and placement limits noted above and dispose of used needles as clinical sharps under local biohazard regulations. This page is informational and does not replace the official instructions for use.

Reviews

There are no reviews yet.

Be the first to review “JBP Nano”
Review now to get coupon!

Your email address will not be published. Required fields are marked